Products > Meters > RD-250 kilovoltmeter

DTE-70/50D hipot tester

RD-250Kilovoltmeter

RD-250 provides a measurement of:- RMS value of the AC voltage of 50 Hz up to 170 kV.- DC average value up to 250 kV.RD-250 can be used to test high-voltage laboratories of electrical and energy profile, as well as scientific research, institutions.Voltage nonsinusoidality ratio must not exceed 8%.Ripple DC voltage must not exceed 1%.The distance from high-voltage inputs of RD-250 to power oject not less than 0.5 m.
ParametersMeasuring range DC voltage (average): from 25 to 250 kV.Measuring range of the AC voltage (RMS): from 15 to 170 kV.Bandwidth on AC metering: 47,5-52,5 Hz.Input impedance of high-voltage unit RD-250 on DC 1600 ± 2 MOhm.Input impedance of high-voltage unit RD-250 on AC, 50 Hz: 200 ± 5 MOhm.Maximum permissible relative error of DC and AC measurement: ± 1,0%.Power supply of HV unit and remote control unit: 4xNi-MH batteries AA of 1.2 V and a capacity of 1.8-2.1 A • h:Supply voltage: 5 ± 0,2V.Radiochannel range: at least 5m.Continuous operation of RD-250 with an input voltage up to 150 kV: up to 8 hours.Operation mode setup time after the power:1 minute.Dimensions: d530x1825 mm;Weight - 36,1 kg