DTE-70/50 testing device

DTE-70/50 high voltage testing device

High-voltage testing device DTE-70/50 (hipot) is designed for insulation testing of high voltage cables with rectified voltage up to 70 kV DC (also non-liquid dielectrics (switchgears, arresters, insulators, dischargers, reclosers, busbars etc.) and other objects with AC voltage up to 50 kV. The hipot tester has analog kilovoltmeter and ammeter scales.


Parameters

  • Output voltage type:                                     DC                   AC        
  • Max output voltage, kV                                 70                    50 
  • Max output current, mA                                15                    45        
  • Output voltage measuring range, kV           0.5-70             0.5-50     
  • Output current measuring range, mA         0-1; 0-15      no measurements       
  • Overcurrent protection, mA, max                  16                   46         
  • HV unit overcurrent protection limit, A          10                   10         
  • Supply voltage                                        220V +/- 22V; 50 (60) Hz
  • Current and voltage measurement error, %    3 (of full reading)
  • Control unit weight, kg                                              11
  • High voltage unit weight, kg                                     44
  • Control unit dimensions, mm                           315x220x365
  • High voltage unit dimensions, mm                   360x285x670

Related products: