SWG-5 Surge Wave Generator
Surge Wave Generators SWG-series are intended for:
- Locating distance to a cable fault using high voltage reflectometer SPARK-4;
- Cable fault location using receiver P-806 or POISK-2016 receivers with acoustic method.
According to statistics, the most common faults in the three-phase underground power cable occur such as "single-phase breakdown" (breakdown of one of the cores to the cable sheath). Breakdown of this type can be "creeping" (intermittent) (ie recovering insulation up to a certain voltage, which is lower than the operating voltage of the cable), and with the "insulation leakage" (insulation resistance decreases up to tens kilohms - hundreds ohms).
Quite frequent cases of breakdown of the two cores one to another and to cable sheath (line-to-line short circuit).
For single-phase breakdowns developers recommend the acoustic method of finding and identifying the fault location.
For the line-to-line short circuit it can be recommended induction method using GZCH-2500 with receiver P-806 or POISK-2016 fault location for "loop" with preliminary insulation burning.
SWG-5 parameters
Testing kV AC/DC 1-5
Surge at 5 kV, Joules 1316 (2632 or 3250 optional)
Surge capacity, µF 130 (260 optional)
Number of stages 1
Operating modes:
- manual single pulse
- automatic surge rate 0,4 Hz
Mains supply, 220 ± 10%, 50/60 Hz
Dimensions, mm 1060x570x1050
Weight, kg 120